Contact us

Hydrogen Glossary

This Hydrogen Glossary explains the terms and acronyms used in equipment specifications, project documents and certification rules. Use it to compare electrolyser quotes, check what a supplier includes and find the EU rules behind renewable and low-carbon hydrogen claims.

A

Active area

The area of an electrode that takes part in the electrochemical reaction. Check which area the manufacturer uses to calculate current density.

Additionality

An EU RFNBO requirement that links fuel production to eligible renewable generation capacity under certain grid electricity sourcing routes. The EU renewable electricity rules cover when the generator began operating and whether it received certain types of public support. Use the RFNBO Readiness Checker to identify which sourcing conditions, exemptions and transitional provisions to check.

Aftermarket services

Support after equipment delivery or installation. It can include inspections, maintenance, spare parts, repairs and replacement stacks.

Alkaline electrolysis (AWE)

Water electrolysis using a liquid alkaline electrolyte, typically potassium hydroxide. Conventional alkaline electrolyser stacks use a diaphragm to separate the hydrogen and oxygen sides. AEM electrolysis and PEM electrolysis use ion-conducting membranes.

Ammonia (NH₃)

A compound of nitrogen and hydrogen used to make fertilisers and other chemicals. The source of the hydrogen used to make ammonia affects production emissions. Ammonia can also carry hydrogen for transport. If the end user needs hydrogen gas, the ammonia must first be cracked.

Ammonia cracking

Breaking ammonia down into hydrogen and nitrogen. The hydrogen may need further purification for the intended application.

Anion exchange membrane (AEM) electrolysis

A type of water electrolysis in which a polymer membrane conducts negatively charged ions, typically hydroxide ions, between the electrodes.

Anode

The electrode where oxidation occurs. In a water electrolyser, this is where oxygen is produced.

Area-specific resistance (ASR)

Electrical resistance multiplied by the active area, typically expressed in Ω·cm². At a given current density, a higher ASR means a greater voltage loss due to resistance.

ATEX

The EU rules for potentially explosive atmospheres. Directive 2014/34/EU covers equipment and protective systems, and Directive 1999/92/EC covers worker protection. Confirm which requirements apply to the equipment and installation.

Autothermal reforming (ATR)

A production process that combines partial oxidation and steam reforming of a hydrocarbon feedstock. Heat released by partial oxidation helps drive the reforming reaction.

Availability

The share of a specified period during which equipment is capable of operating. Equipment can be available while idle because of electricity prices or low demand.

B

Balance of plant (BoP)

The equipment that supports operation of the electrolyser stack or plant, such as power conversion, cooling, water treatment, gas separation and controls. Check what each supplier includes and what the site must provide.

Balance of stack (BoS)

Equipment supplied with the stack to connect, operate or monitor it, such as piping, sensors and instrumentation. The scope varies by supplier and can overlap with the balance of plant.

Bankability

The extent to which a project or technology meets lender and investor requirements. Common considerations include performance evidence, warranties, contracted revenues and how risks are allocated.

Bidding zone

An area of an electricity market in which participants can trade electricity without allocating transmission capacity between areas. EU RFNBO geographical correlation rules use bidding zones to assess where qualifying electricity is generated.

Bipolar plate

A conductive plate between adjacent cells in a stack. It connects the cells electrically and, depending on the design, helps distribute fluids or gases.

Black and brown hydrogen

Informal labels for hydrogen made from coal. Black commonly refers to hard coal and brown to lignite, although usage varies.

Blending

Mixing hydrogen with another gas, usually natural gas. A blend’s hydrogen percentage by volume differs from its percentage by energy content.

Blue hydrogen

An informal label for hydrogen made from fossil fuels, typically natural gas, with carbon capture and storage. Its emissions depend on how much CO₂ the process captures, the energy it uses and upstream methane emissions.

Boil-off gas

Gas formed as heat enters a tank containing a cryogenic liquid such as liquid hydrogen, causing some of the liquid to evaporate.

Boundary of supply

The agreed division between the supplier’s package and equipment or work provided by others. It identifies where utilities, hydrogen and controls connect.

Brownfield project

A development at an existing industrial site that may use site utilities, infrastructure or permits. A greenfield project starts on a new site.

C

Capacity factor

Actual output over a period divided by the output possible at full rated capacity over the same period. For a hydrogen production figure, use hydrogen output. For an electrical load factor, divide actual electricity consumption by the energy the equipment would use at rated electrical input over the same period.

Capital expenditure (CAPEX)

Upfront spending on equipment, construction and other capital items. A stack price, an installed electrolyser price and a total project cost cover different scopes.

Carbon capture and storage (CCS)

Separating CO₂ from a process stream or exhaust and transporting it for long-term geological storage.

Carbon capture, utilisation and storage (CCUS)

The capture of CO₂ for use in products or processes, or for long-term storage. The emissions impact depends on the capture rate, the intended use and how long the CO₂ stays out of the atmosphere.

Carbon intensity

Greenhouse gas emissions per unit of output, such as kg CO₂e/kg H₂ or g CO₂e/MJ. The time period, system boundary and calculation method determine what the figure represents.

Catalyst

A material that speeds up a reaction. In an electrolyser, catalysts at the electrodes help produce hydrogen and oxygen at a lower operating voltage for a given current.

Cathode

The electrode where reduction occurs. In a water electrolyser, this is where hydrogen is produced.

Cell voltage

The electrical potential difference across one cell. At the same current, a cell with a higher operating voltage draws more electrical power.

Certification scheme

A framework with rules and independent audits for verifying a claim such as RFNBO compliance. Check which standards and geographical areas the scheme covers.

Chain of custody

The method for tracking a fuel’s origin or sustainability attributes through the supply chain. Mass balance is one example.

Clean hydrogen

An umbrella term used differently across policies and markets. Check the applicable emissions threshold, calculation method and eligibility rules.

Cold start

Starting an electrolyser after it has shut down and cooled. Compare quoted start times from the same initial temperature and to the same endpoint, such as the first delivery of hydrogen that meets the agreed specification.

Commissioning

Testing and verifying installed equipment and its interfaces before handover or commercial operation.

Compressed gaseous hydrogen (CGH₂)

Hydrogen stored or transported as a gas at elevated pressure, for example in cylinders, tube trailers or multi-element gas containers.

Compressed hydrogen storage

Holding gaseous hydrogen at elevated pressure in suitable vessels. Usable inventory depends on the operating pressure range and delivery conditions.

Compression

Increasing the pressure of hydrogen gas for storage, transport or use. How much compression is needed depends on the electrolyser outlet pressure and the delivery requirement.

Conductivity

A measure of how readily a material carries electric charge. In an electrolyser, ionic conductivity describes how readily ions move through an electrolyte or membrane.

Containerised electrolyser

An electrolyser system housed in one or more container-style enclosures. When specifying a containerised electrolyser system, check which utilities, foundations and other equipment the site must provide.

Current density

Electrical current per unit of active electrode area, commonly given in A/cm². It influences how much hydrogen a cell produces per unit of area.

Curtailment

Reducing generation below what a power plant could otherwise produce, for example when the grid cannot take the output.

D

Degradation

Loss of performance over time. In an electrolyser stack it can appear as higher voltage at the same current. Compare degradation rates alongside the test conditions and operating profile.

Deionised water (DI water)

Water treated to remove dissolved ions. Electrolyser suppliers specify feedwater quality limits for their equipment.

Delivery pressure

The hydrogen pressure at the agreed handover point. Confirm the point of measurement and whether the pressure is absolute, bar(a), or gauge, bar(g). Gauge pressure is measured relative to atmospheric pressure.

Dew point

The temperature at which water vapour begins to condense at a specified pressure. It describes how dry a gas is when the measurement pressure is given.

Diaphragm

A porous separator in a conventional alkaline electrolyser. Ions move through electrolyte in its pores, while the separator limits mixing of hydrogen and oxygen.

Direct connection

An electricity supply arrangement in which a direct line connects the generator to the fuel production installation, or both are part of the same installation. For EU RFNBO eligibility, check the commissioning, grid connection and metering conditions in Article 3 of the EU renewable electricity rules.

Direct electrification

Using electricity directly in an application, for example with an electric motor or heat pump. It is an alternative to first converting electricity into hydrogen for the same end use.

Direct-reduced iron (DRI)

Iron made by removing oxygen from iron ore in the solid state. In hydrogen-based steel production, hydrogen removes the oxygen, and the resulting iron can be used in an electric arc furnace.

Dryer

Equipment that lowers the water vapour content of a hydrogen stream to meet a specified moisture limit.

Dynamic operation

Running an electrolyser at varying load or with start-stop cycles, for example to follow renewable output or electricity prices. Minimum load, ramp rate and restart times define parts of its operating range.

E

E-ammonia

Ammonia made using hydrogen from electrolysis. When sourcing hydrogen for ammonia production, check the electricity source and production process. Both affect emissions and eligibility under renewable-fuel rules.

E-fuels (electrofuels)

Fuels made using hydrogen from electrolysis. The hydrogen is often combined with a carbon source to make products such as e-methanol, e-methane or synthetic kerosene.

E-methane

Synthetic methane commonly made by reacting hydrogen from electrolysis with CO₂. Its lifecycle emissions depend on electricity, CO₂ sourcing and methane losses.

E-methanol

Methanol made with hydrogen from electrolysis and a carbon source, commonly CO₂. It can be used as a chemical feedstock or fuel.

E-SAF

Synthetic sustainable aviation fuel made with hydrogen from electrolysis and a carbon source. Synthetic kerosene can qualify when it meets the applicable fuel and sustainability requirements.

Electrical efficiency

The energy in the hydrogen produced divided by the electricity consumed, expressed as a percentage. At 50 kWh/kg H₂, the same equipment has an efficiency of about 67% on a lower heating value (LHV) basis and 79% on a higher heating value (HHV) basis. When comparing stack efficiency or system efficiency figures, match the heating-value basis, equipment boundary and operating conditions. State any external heat input separately.

Electrochemical cell

A single reaction unit containing two electrodes and an ion-conducting medium. An electrolyser stack combines multiple cells.

Electrode

A conducting surface where an electrochemical reaction occurs. In a water electrolyser, the cathode produces hydrogen and the anode produces oxygen.

Electrolyser (electrolyzer)

Equipment that uses electricity to drive electrolysis. In hydrogen production, it commonly refers to water-splitting equipment. Specifications may refer to a stack, a system or a complete plant.

Electrolyser stack

An assembly of electrochemical cells that splits water into hydrogen and oxygen. Alkaline electrolyser stacks, for example, need a DC power supply and supporting equipment to operate as part of a system.

Electrolyser system

One or more stacks and the supporting equipment required to produce hydrogen. For a containerised electrolyser system or other system configuration, check whether the supplier includes the transformer, rectifier, water treatment, cooling, drying, purification and compression. Use the same equipment boundary when comparing quoted power consumption.

Electrolysis

Using electricity to drive a chemical reaction. Water electrolysis produces hydrogen and oxygen from water.

Electrolyte

A medium that conducts ions between electrodes. It can be a liquid solution, a polymer membrane or a ceramic, depending on the technology.

Embrittlement

A loss of ductility or resistance to cracking that can occur when susceptible materials are exposed to hydrogen. Assess materials for the intended pressure, temperature and loading conditions.

Emergency shutdown (ESD)

A system or function that brings equipment to a defined safe state when specified abnormal conditions occur or when manually activated.

Energy carrier

A substance or medium that stores and delivers energy. Hydrogen is an energy carrier and can also be an industrial feedstock.

Engineering, procurement and construction (EPC)

A contract scope that covers designing a facility, procuring equipment and materials, and building it. Responsibility for commissioning and guarantees depends on the contract.

European Hydrogen Bank

An EU initiative to support hydrogen investment. Its renewable hydrogen auctions offer production support to eligible projects under the terms of each funding round.

F

Factory acceptance test (FAT)

A test carried out before shipment to verify equipment against agreed criteria. The contract or test protocol sets the test scope and acceptance limits.

Faradaic efficiency

The share of electrical charge that produces the intended product. For an electrolyser, divide measured hydrogen output by the theoretical output for the same charge passed.

Feedstock

A raw material consumed in a process. Hydrogen is a feedstock for products such as ammonia, while natural gas can be the feedstock used to make hydrogen.

Final investment decision (FID)

The formal decision to commit capital and proceed with a project. It typically follows work on engineering, permits, financing and major contracts.

Front-end engineering design (FEED)

Engineering work that defines a project’s technical scope, key interfaces and cost basis before detailed design and construction.

Fuel cell

A device that converts the chemical energy of a fuel into electricity through electrochemical reactions. A hydrogen fuel cell also produces water and heat.

Fuel specification

A set of quality requirements for a fuel at an agreed point in the supply chain. It can specify minimum hydrogen purity and maximum levels of individual contaminants.

Full-load hours

Total output divided by rated output per hour. This gives the equivalent hours at full load. Actual hours in operation can be higher when equipment spends time at part load.

G

Gas crossover

Movement of hydrogen or oxygen across the separator into the opposite gas stream. Crossover affects gas purity and can constrain the operating range.

Gas-liquid separator

Equipment that separates produced gas from circulating water or electrolyte before downstream gas treatment.

Gasification

Converting a carbon-containing feedstock such as coal, biomass or waste into a gas mixture that contains hydrogen and carbon monoxide. Further processing can increase hydrogen yield and purify the output.

Geographical correlation

An EU RFNBO requirement that links qualifying renewable electricity to the location of fuel production. The EU renewable electricity rules can allow sourcing within the same bidding zone or from certain other bidding zones if the relevant conditions are met. The RFNBO Readiness Checker can help identify what to verify for a project.

GHG savings

The percentage reduction in greenhouse gas emissions against a defined reference. The applicable method determines the reference, the emissions counted and the units used.

Green hydrogen

A widely used term for hydrogen made by water electrolysis powered by renewable electricity. Formal claims such as EU RFNBO eligibility follow additional criteria.

Green steel

A market term for steel made with lower greenhouse gas emissions. One route uses hydrogen to reduce iron ore and an electric arc furnace to make steel. Ask for the emissions intensity and how it was calculated.

Grey hydrogen

An informal label for hydrogen made from fossil fuels without carbon capture, most commonly from natural gas. This route has traditionally supplied hydrogen for oil refineries. Coal-derived hydrogen often has separate colour labels.

Grid-connected electrolysis

Electrolysis supplied with electricity through the power grid. For EU RFNBO claims, check the applicable sourcing route and what evidence it requires.

Guarantee of origin (GO)

An electronic certificate used to show customers the origin of energy. EU RFNBO certification requires evidence under its own sourcing and emissions rules.

H

H₂-ready

A supplier or project claim that equipment can handle hydrogen now or after specified modifications. Check the permitted hydrogen concentration, materials, operating conditions and conversion scope.

Hazard and operability study (HAZOP)

A structured team review of how deviations from intended operating conditions could create hazards or operating problems.

Hazardous area classification

Identifying areas where an explosive atmosphere may occur and classifying them for equipment selection and design.

Higher heating value (HHV)

The heat released when a fuel burns, including the heat recovered when the water formed during combustion condenses. Hydrogen’s HHV is about 39.4 kWh/kg. Check whether quoted electrolyser efficiency uses HHV or lower heating value (LHV).

Hydrogen (H₂)

The lightest element. Gaseous hydrogen usually consists of molecules with two hydrogen atoms. Industrial uses include fertiliser production, refining, steelmaking and fuel production.

Hydrogen blending limit

The maximum hydrogen share allowed in a gas mixture. Check the applicable network rules, equipment specifications and whether the limit is stated by volume.

Hydrogen carrier

A substance that can transport hydrogen chemically bound within it. Examples include ammonia and liquid organic hydrogen carriers. Releasing hydrogen for use can require extra processing.

Hydrogen hub

A regional cluster that connects hydrogen producers, users and infrastructure such as storage, pipelines or refuelling.

Hydrogen leak detection

Monitoring for unintended hydrogen releases using detectors or other monitoring systems selected for the equipment and site.

Hydrogen pipeline

A pipeline designed or assessed to transport hydrogen. Materials, joints, operating pressure and gas quality requirements affect whether existing infrastructure can be reused.

Hydrogen purification

Removing impurities from a hydrogen stream to meet the specification for its intended use. Gas drying, impurity removal and purity testing may be separate steps.

Hydrogen purity

The proportion of hydrogen in a gas stream, usually expressed as a mole or volume fraction. Ask for individual impurity limits and the sampling point, especially when the end use is sensitive to water, oxygen or sulphur compounds.

Hydrogen reduction

Using hydrogen to remove oxygen from a material. One application is hydrogen-based ironmaking, where hydrogen reacts with iron oxide to form iron and water.

Hydrogen refuelling station (HRS)

A facility that stores or receives hydrogen and dispenses it into vehicles at a specified pressure and fuel quality.

Hydrogen valleys

Regional projects that link local hydrogen production with users in one or more sectors. They often include shared infrastructure. The term is widely used in European hydrogen programmes.

Hydrogen value chain

The activities that connect hydrogen production to end use, including conditioning, storage, transport and, for some routes, conversion into and out of a carrier.

Hydrogenation

Adding hydrogen to a molecule, typically with a catalyst. Industrial applications include refining, chemical manufacture and processing fats and oils.

Hydrotreating

Using hydrogen in an oil refinery to remove impurities such as sulphur and improve the quality of fuel streams.

I

Interlock

A control condition that prevents an action or automatically changes a system’s state if a defined condition is met.

Islanded operation

Operating an electrolyser and its power supply independently of the wider electricity grid. Local generation and any supporting storage must cover operating needs.

K

kg H₂/h

Kilograms of hydrogen produced or delivered per hour. To compare this mass flow rate with Nm³/h, confirm the reference temperature and absolute pressure used for the volume figure. The hydrogen calculators convert between mass and volume.

kWh/kg H₂

Kilowatt-hours of energy used per kilogram of hydrogen produced. When comparing supplier figures, check whether they measure DC input at the stack or AC input at the system boundary, and which auxiliary equipment they include.

L

Levelised cost of hydrogen (LCOH)

The discounted lifetime cost of production divided by discounted lifetime hydrogen output, usually expressed in €/kg or $/kg. Compare assumptions about electricity, operating hours, financing and the point at which hydrogen is delivered.

Lifecycle assessment (LCA)

A method for assessing environmental impacts across defined stages of a product or process. Results depend on the system boundary, data and treatment of co-products.

Liquid hydrogen (LH₂)

Hydrogen cooled to a cryogenic liquid. It is denser than compressed gas, but liquefaction requires energy and stored liquid can generate boil-off.

Liquid organic hydrogen carrier (LOHC)

An organic liquid that temporarily binds hydrogen through a chemical reaction. Hydrogen can be released later for use, typically with heat and a catalyst.

Low-carbon hydrogen

Under EU Directive 2024/1788, hydrogen whose energy comes from non-renewable sources and meets a greenhouse gas emissions savings threshold of at least 70% against the specified fossil comparator. Delegated Regulation (EU) 2025/2359 sets the calculation method.

Low-emissions hydrogen

Hydrogen produced with a relatively low greenhouse gas intensity. Thresholds, eligible pathways and accounting boundaries vary by organisation and policy.

Lower explosive limit (LEL)

The lowest concentration of a flammable gas in a specified oxidising mixture that can propagate a flame under stated conditions. Lower flammability limit (LFL) is often used for the same threshold.

Lower heating value (LHV)

The heat released when a fuel burns with the water formed during combustion remaining as vapour. Hydrogen’s LHV is about 33.3 kWh/kg. Whether you use LHV or higher heating value (HHV), compare both efficiency figures on the same basis.

M

Mass balance

A chain-of-custody method that tracks the quantities and sustainability attributes of inputs and outputs when physical batches can be mixed, subject to the scheme’s rules.

Methanation

Converting hydrogen and carbon oxides into methane. It is one route to e-methane when the hydrogen comes from electrolysis.

Methane pyrolysis

Splitting methane into hydrogen and solid carbon using heat. The lifecycle emissions depend on the methane supply, energy inputs and treatment of the solid carbon.

Minimum load

The lowest load at which an electrolyser can operate under specified conditions while meeting relevant operating and gas-quality limits. Check whether the figure refers to one stack or the plant.

Modular electrolyser

An electrolyser built from repeatable units that can be combined for the required capacity. The balance of plant can be shared, duplicated or sized separately.

Multi-element gas container (MEGC)

A transportable assembly of multiple cylinders or tubes connected by a manifold. It can carry compressed hydrogen by road or other approved modes.

MW and MWh

A megawatt (MW) is a unit of power. A megawatt-hour (MWh) is a unit of energy. An electrolyser drawing 1 MW for one hour uses 1 MWh of electricity.

N

Nm³ and Nm³/h

A normal cubic metre (Nm³) is a gas volume expressed at stated reference conditions. Nm³/h expresses flow on the same basis. A common convention is 0 °C and 1.01325 bar absolute, under which 1 kg of hydrogen is about 11.1 Nm³. Confirm the supplier’s reference temperature and absolute pressure before using the hydrogen calculators to convert volume to mass.

O

Offtake agreement

A contract in which a buyer agrees to purchase hydrogen or a derivative. It can specify volume, price, product quality, delivery terms and conditions that must be met before purchases begin.

Operating expenditure (OPEX)

Recurring costs of running a project, including electricity, water, labour and maintenance. Whether stack replacements are counted here depends on the financial model.

Overpotential

The difference between an electrode’s operating potential and its equilibrium potential for a reaction. Its magnitude describes the extra voltage needed at the electrode to drive the reaction at the stated rate.

P

Pink hydrogen

An informal label for hydrogen made using nuclear energy, often through electrolysis. Other colour names are also used for nuclear-powered hydrogen.

Platinum group metals (PGMs)

A group of six metals that includes platinum and iridium. Some electrolyser designs use these metals as catalysts. A PGM-free claim should identify whether it refers to a component or the full system.

Potassium hydroxide (KOH)

An alkaline compound commonly dissolved in water to make the electrolyte for conventional alkaline electrolysers.

Power purchase agreement (PPA)

A contract to buy electricity on agreed terms. A renewable PPA may form part of the evidence for RFNBO eligibility under the applicable procurement pathway.

Power-to-gas (PtG)

Using electricity to produce a gaseous fuel, such as hydrogen from electrolysis or methane made from hydrogen and CO₂.

Power-to-liquid (PtL)

Using electricity, typically through hydrogen from electrolysis, to make liquid fuels such as synthetic aviation fuel or methanol.

Power-to-X (PtX)

Using electricity to make another product or energy carrier. In the hydrogen sector, products include hydrogen, ammonia, methanol and synthetic fuels.

Pressure swing adsorption (PSA)

A gas purification process that uses changes in pressure to capture and release impurities on a solid adsorbent. It can be used to purify hydrogen-rich gas.

Pressurised electrolysis

Electrolysis designed to produce gas at elevated pressure. The outlet pressure can influence how much downstream compression the project needs.

Proof of origin

Documentation showing where a product or energy input came from. The accepted evidence depends on the claim, market and scheme.

Proof of sustainability (PoS)

Documentation that records a fuel consignment’s compliance attributes under a certification scheme. The required content and terminology follow the scheme’s rules.

Proton exchange membrane (PEM) electrolysis

Water electrolysis using a solid polymer membrane that conducts protons. PEM can also stand for polymer electrolyte membrane.

R

Ramp rate

The speed at which an electrolyser can raise or lower its load, often stated as a percentage of rated load per second or minute. Check the load range, starting state and whether the figure is for stack power, system power or hydrogen flow.

Rectifier

Equipment that converts alternating current (AC) to the direct current (DC) required by an electrolyser stack.

Renewable Energy Directive (RED III)

The common name for Directive (EU) 2023/2413, the 2023 amendment to the EU Renewable Energy Directive. It sets renewable energy targets and contains provisions affecting RFNBO use in industry and transport.

Renewable hydrogen

Hydrogen produced from renewable energy sources. For a claim under the EU Renewable Energy Directive, check whether the hydrogen meets the rules for renewable fuels of non-biological origin (RFNBOs).

Replacement stack

A stack installed to replace an existing unit while retaining some or all of the wider system. Compatibility depends on electrical, mechanical, controls and process interfaces.

RFNBO (renewable fuel of non-biological origin)

An EU category for liquid and gaseous fuels whose energy comes from renewable sources other than biomass. The European Commission’s renewable hydrogen guidance explains how sourcing and emissions rules apply to hydrogen and eligible derivatives, including imports into the EU. The fuels must deliver at least 70% lifecycle greenhouse gas savings. The EU lifecycle emissions methodology uses a fossil comparator of 94 g CO₂e/MJ, which puts the maximum at 28.2 g CO₂e/MJ. Use the RFNBO Readiness Checker to identify what your project still needs to verify.

S

Salt cavern storage

Underground storage of gaseous hydrogen in a cavity developed within a salt formation. Suitability depends on local geology and the storage project design.

Site acceptance test (SAT)

Testing at the installation site to verify that delivered equipment and its interfaces meet agreed acceptance criteria.

Solid oxide electrolysis cell (SOEC)

A high-temperature electrolysis cell with a ceramic electrolyte. It can split steam to produce hydrogen. Some designs can also co-electrolyse steam and CO₂ to make synthesis gas.

Specific energy consumption (SEC)

The energy used per unit of hydrogen produced, often stated in kWh/kg H₂ or kWh/Nm³. Compare figures at the same load, outlet pressure and gas quality. Check whether they cover DC stack input or AC system input. Confirm the gas reference conditions before using the hydrogen calculators to convert between volume and mass.

Stack efficiency

The energy in the hydrogen produced divided by the DC electricity supplied to the stack, on an LHV or HHV basis. Compare electrical efficiency figures on the same heating-value basis, at the same load and under the same test conditions. Check whether the quoted figure is for a new stack or another point in its service life. For the wider equipment package, check system efficiency.

Stack lifetime

The time or operating hours until a stack reaches an agreed performance or replacement criterion under a specified duty cycle.

Steam methane reforming (SMR)

Making a hydrogen-rich gas by reacting methane with steam. A water-gas shift step commonly increases hydrogen yield, and purification separates the hydrogen from the gas mixture.

Sustainable aviation fuel (SAF)

Aviation fuel from eligible sources that meets the applicable fuel quality and sustainability rules. Eligible pathways can include fuels made from biological feedstocks and synthetic fuels.

Synthesis gas (syngas)

A gas mixture mainly containing hydrogen and carbon monoxide. It can be processed to make more hydrogen or used as a feedstock for products such as methanol.

System efficiency

The energy in the hydrogen produced divided by the energy input at the stated system boundary, on an LHV or HHV basis. For an AC electrical figure, check whether the boundary includes the transformer, rectifier, cooling, water treatment, drying, purification and compression. These details matter when comparing the figure with DC stack efficiency. If the process uses external heat, check how it is reported and what the specific energy consumption figure covers.

T

Temporal correlation

An EU RFNBO requirement to match the timing of fuel production with qualifying renewable electricity generation or eligible storage. Where it applies, the EU renewable electricity rules generally permit monthly matching through 31 December 2029 and require hourly matching from 1 January 2030. Use the RFNBO Readiness Checker to review your project’s matching arrangements, then confirm any exceptions or earlier national application.

Total cost of ownership (TCO)

The cost of acquiring, operating and maintaining equipment over a defined period. It may include energy, consumables, service, replacements and end-of-life costs.

Tube trailer

A road trailer fitted with high-pressure tubes for transporting compressed hydrogen, for example to an industrial site or refuelling station.

Turndown ratio

Maximum stable output divided by minimum stable output under stated conditions. An electrolyser that can operate from 100% down to 20% of rated output has a turndown ratio of 5:1. Confirm whether the figure applies to a stack or the whole system.

Turquoise hydrogen

An informal label for hydrogen produced by methane pyrolysis. Lifecycle emissions depend on the methane supply, energy inputs and treatment of the solid carbon.

U

Utilisation rate

How intensively equipment is used over a period. It can mean time in operation or output relative to rated capacity, so check how the figure was calculated.

V

Volumetric energy density

Energy stored per unit of volume, such as kWh/m³. For hydrogen gas it varies with pressure and temperature. Compare figures on the same heating-value basis.

Voluntary scheme

A certification scheme that verifies particular sustainability or emissions claims. Check the European Commission’s register of recognised voluntary schemes to see whether a scheme’s current recognition covers your fuel and supply chain.

W

Warm start

Restarting an electrolyser from standby, with some operating conditions maintained. Check how the supplier defines the standby conditions and when it considers the restart complete.

Waste heat recovery

Capturing heat released by an industrial process for another use, such as process preheating or district heating. Its usefulness depends on temperature and demand.

Water consumption

The water used per unit of hydrogen produced, or over a stated period, within a defined boundary. When comparing supplier figures, check whether they measure treated water fed to the stack, total site intake or net consumption after any water is returned. Treatment losses and cooling can change the site requirement.

Water-gas shift reaction

A reaction between carbon monoxide and steam that produces additional hydrogen and CO₂. It is commonly used after reforming.

Well-to-gate emissions

Emissions from upstream resource extraction or supply through to the production facility’s exit point. Check which stages the assessment includes and where it places the boundary.

White hydrogen (natural hydrogen)

Hydrogen that occurs naturally in geological formations. It is also called native or geological hydrogen.

Contact us

Each hydrogen project is different and tailored to match the client’s needs. Contact us for a consultation with one of our engineers today.

    Eliminate CO2 emissions by switching to green hydrogen | Stargate Hydrogen

    Eliminate CO2 emissions by switching to green hydrogen

    Tailored solutions to match any application | Stargate Hydrogen

    Tailored solutions to match any application

    Reliable, industrially-proven technology | Stargate Hydrogen

    Reliable, industrially-proven technology

    Cost-effective, versatile, and scalable | Stargate Hydrogen

    Cost-effective, versatile, and scalable

    Sign up for our newsletter